Heartland Bakeware U109760-02 Range User Manual


 

Installation Instructions
   
 
   
  
Your range is shipped with a 4-prong plug to be
used in a NEMA 14-50R receptacle.

Locate the electric supply as illustrated.
Recommended acceptable electrical outlet area. Orient the electrical
receptacle so the length is parallel to the floor.
When connecting using a NEMA 14-50R
receptacle, if possible position it so that it can
be accessed through the opening at the rear of
the drawer cavity. The range can then be easily
disconnected for servicing etc.
Plug the range power cord into a properly
grounded wall receptacle.
    
    
To remove the electrical connection cover
first remove the screws on the top and bottom
edges. The cover has two side and one bottom
location tags.
Slide the cover down to free the side tags.
Free from the bottom tag.
When refitting the cover first locate it on the
bottom tag second locate the two side tags and
then replace the screws.
  
Disconnect the supplied power cord from
the terminal block and ground post. Keep
the terminal block parts; you will need them.
Remove the strain relief clamp from the power
cord and remove the power cord and strain relief
clamp from the mounting bracket.
The range is shipped with reducer plates to
give a 1 1/8’’ diameter opening for conduit
connection. Find the reducer plates in the
conversion kit and fit them to the mounting
bracket.
Fit a squeeze connector (not supplied with
the range), to your conduit. Insert the conduit
through the reducer plates on the mounting
bracket. Allow enough slack to easily attach the
wires to the terminal block.