– 14 –
2. Remove the feed cylinder. The feed cylinder guides (see Fig. 7) OR the three knives (see Fig. 8)
may be removed for cleaning by unscrewing the nuts (see Fig's. 7 & 8) with the wrench provided.
Rinse all parts with lukewarm water.
3. Remove the cutting tool.
4. If you have used a dicing grid, before removing, push the remaining leftovers through the TOP of
the dicing grid with the nylon brush provided. Pushing the leftovers through from the underside of
the dicing grid may damage the grid.
5. Remove the dicing grid and ejector plate; rinse in lukewarm water.
6. Wipe the knife chamber with a clean damp cloth. Wipe dry with a clean dry cloth.
7. Return the cutting tools to the wall rack. Lower the ejector plate onto the knife shaft. Press all the
way down and turn until the plate is in the locked position.
8. Replace the feed cylinder and feed hopper or pusher plate attachment.
MAINTENANCE
WARNING: TURN THE MACHINE OFF AND UNPLUG THE ELECTRICAL CORD BEFORE DOING
ANY MAINTENANCE.
Routinely inspect the machine to ensure that it is in proper working order. Plates must be clean, intact,
and sharp.
The knife shaft and the hinge pins should be regularly lubricated with a drop of mineral oil, NOT
COOKING OIL.
REPLACEMENT DICING GRIDS
Depending on usage, dicing grids become dull from wear with an average life expectancy from 8 to 18
months. Dicing grids cannot be resharpened and are therefore expendable. Replacement dicing grids
are available from your local Hobart Service Office.