Hobart HBA1E Convection Oven User Manual


 
– 23 –
Fig. 1
Inspect Oven Lamps
1. Lamps should be on when oven is powered.
2. If not, replace lamps (Fig. 1).
A. Remove lens cover by turning out of lamp housing.
B. Remove oven lamp by turning lamp out of lamp
socket.
3. Reverse the procedure to install new lamps.
OWNER PREVENTIVE MAINTENANCE PROCEDURE
INTRODUCTION
This customer preventive maintenance (PM) section includes procedures to inspect for proper
operation and cleaning of components. Owner Preventive Maintenance Procedures are written for gas
ovens. They can also be used for electric ovens by omitting the steps that refer to components found
only on gas ovens. Customer PMs should be conducted bi-monthly per OSHA Bakery Oven Inspection
Standard 29 CFR 1910.263(l)(9)(ii). A convenient PM Checklist is provided at the end of this section.
NOTE: This PM procedure does not discuss repair or replacement of components. Upon completion
of the PM procedure you will need to contact a qualified servicer for any needed repairs.
Tools Used For Inspection Procedure
Standard set of hand tools
Vacuum cleaner - shop vac
PREVENTIVE MAINTENANCE PROCEDURE
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES. THERE MAY BE MULTIPLE CIRCUITS. BE SURE ALL
CIRCUITS ARE DISCONNECTED.
WARNING: SHUT OFF THE GAS BEFORE SERVICING THE UNIT.
WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TEST OR
MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION
AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER AND
FOLLOW LOCKOUT / TAGOUT PROCEDURES, ATTACH TEST EQUIPMENT AND REAPPLY
POWER TO TEST.