– 22 –
MAINTENANCE
WARNING: TURN OVEN OFF AND UNPLUG ELECTRICAL CORD BEFORE PERFORMING ANY
MAINTENANCE.
The fan motor comes with sealed bearings and requires no lubrication.
The door mechanism requires occasional lubrication with mineral oil.
If this oven is placed on casters, it should be connected to the supply piping with the proper disconnect
device and restraint. If it is necessary to disconnect the restraint, first turn off the gas supply.
Reconnect the restraint before turning the gas supply on and returning the oven to its original
installation position.
Annually check the flue, when cool, to be sure it is free of obstructions.
REPLACING LAMPS
• Remove all racks by pulling forward, lifting up and out.
• Remove the right rack support by lifting up.
• Unscrew glass dome(s) from light body.
• Replace the bulb(s).