TECHNICAL DETAILS
Model Cooker 60 80 100 120
Rated input kw (gross) 17.6 22.2 29.7 37.3 45.5
Rated output kw (gross) - 17.6 23.4 29.3 35.2
Burner Cooker Boiler - 60k Boiler - 80k Boiler - 100k Boiler - 120k
Gas Volume m 3/jr 1.68 2.11 2.84 3.56 4.34
Co2 % 8.5-9.0 7.0-8.0 8.0-8.5 8.5-9.0 8.5-9.0
Starting current - Amp 0.422 0.422 0.8 0.8 0.83
Running current - Amp 0.33 0.33 0.48 0.48 0.74
Electrical power consumption 230v 50 Hz 95 watts
Gas Type Natural Gas 20mbar G20
Gas Cat I
2H
for use in GB, IE (Great Britain and Eire)
Weight - dry kg 512kg
Water content - Litre 38
Flow and Return NA 2 x 1
1
/
4”
BSP
Max Operating Pressure (PMS) NA 3.0 bar
Operating Temparature Range NA 60 - 80°C
Conventional Flue 0.05 +/- 0.02” WG
Operating Range 12.45 +/- 4.98 Pa
Water side resistance - mbar
10°C diff NA 26
20°C diff NA 8.3
Flue sockets - Dia. 145mm Inside Flue Dia. 5” (125mm)