INSTALLATION INSTRUCTIONS
1.1 The Redfyre range of Central Heating cookers is a range of
floor mounted storage central heating cookers with a fixed
rate cooker burner and the option of four fixed rate central
heating outputs depending on heating load. 60, 80, 100 x
12,000 BTU.
1.2 The cooker has two independent matched premix gas
burners which are exceptiantly quiet in operation. One heats
the cooker and the other the central heating and are
controlled via thermostats with the cooker being controlled
bu an electronic programmer within the unit
1.3 The boiler side of the cooker has been designed for use on
open vent or sealed systems. If it is to be used on a sealed
water system up to a maximum working pressure of 3bar,
additional safety devices will be required.
1.4 This cooker is suitable for use on natural gas only and must be
connected to a conventional flue.
1.5 Incorporated with the appliance are:-
a) User adjustable controls for cooking oven and
central heating water temperature.
b) Burner running indicator neons
c) Overheat thermostats (with neon indicators) on both the
cooker and boiler, with an additional pump over run
thermostat on the central heating circuit.
d) An integral electronic programmer to control the cooker
on and off times.
e) A boiling spot and simmer spot in addition to a top oven
(with thermostat control) and a separate lower oven
which operates at approximately 100° C lower than the
top oven
f) A blocked flue thermostat which prevents the unit
operating if a blocked flue occurs.
g) Two efficient and quiet premix gas burners with fully
automatic ignition provide outputs with very Low No
X
values.
1.6 All servicing can be carried out from the front and top of the
appliance, thus allowing the cooker to be fitted between
kitchen units. The front mounted flue-cover permits easy
access for the removal of the flue baffles and cleaning of
heating surfaces.
1.7 This appliance has been designed to conform to European
Directive/Standards BED, LVD, EN, EMC and GAD.
1.8 The installation of this central heating cooker MUST be
carried out by a competent person in accordance with the
relevant requirements of the current issue of the Gas Safety
(Installation and Use) Regulations, the Building Regulations,
the IEE Wiring Regulations, the Building Standards (Scotland)
Regulations (applicable in Scotland), Local Water Company
Byelaws, Health and Safety Document No 635.
Detailed recommendations are contained in the current
issues of the following British Standards BS 5440 Pts 1 & 2,
BS 5449, BS 5546, BS 6700, BS 6798, BS 6891 and BS
7593.
1.9 Health and Safety at Work Act
The installer should be aware of his responsibilities under the
Act and provide, where necessary, appropriate protection for
persons carrying out the installation.