Hoshizaki 73202 Ice Maker User Manual


 
33
C. Settings and Adjustments
1. Default Dip Switch Settings
The S1 dip switch settings are factory-set to the following positions:
Dip Switch No. 1 2 3 4 5 6 7 8 9 10
DCM-270BAH(-OS) OFF OFF OFF OFF ON OFF OFF OFF OFF OFF
Bin Control Shutdown Delay (infrared sensor)
Continuous Dispensing Timer
(Do not adjust on DCM-270BAH-OS)
Drain Frequency Control
Bin Control Selector
Bin Control Shutdown Delay (mechanical) and Periodic Agitation
of Storage Bin
Normally off (factory use)
2. Bin Control Shutdown Delay (Infrared Sensor) (S1 dip switch 1, 2, 3)
NOTICE
Do not adjust. Setting not used on this model. When dip switch 7 is off, 1, 2, and 3
are ignored.
Factory set. DCM-270BAH(-OS) does not use a bin control with an infrared sensor.
The appliance uses a bin control with a mechanical microswitch for ice level control.
3. Drain Frequency Control (S1 dip switch 4)
The appliance is factory set for optimum performance with the 1-in-1 drain cycle (S1 dip
switch 4 in the "OFF" position). This setting allows for removal of sediment from the
evaporator without interrupting the icemaking process. 1-in-12 drain cycle is available.
S1 Dip Switch Setting
Drain Timer Interval Drain Valve Open
No. 4
OFF (1-in-1) 1 Hour 2 Seconds
ON (1-in-12) 11 Hours 45 Minutes 10 Minutes