Hoshizaki Condensing Unit Models SRK-14J/3 Ice Maker User Manual


 
19
3. Controls and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact Hoshizaki
Technical Support at 1-800-233-1940.
a) Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch
Dip Switch No. 1 2 3 4 5 6 7 8 9 10
KMS-1401MLJ OFF OFF OFF ON ON ON ON OFF OFF OFF
S5 Dip Switch (Do Not Adjust)
Dip Switch No.
1 2 3 4 5
KMS-1401MLJ ON ON OFF OFF OFF
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reads 48°F (9°C) at the evaporator
outlet and the control board reads the thermistor's 3.9 kΩ signal. The harvest timer is
factory set, and generally no adjustment is required. However, a setting longer than the
factory setting may be advised in cases where the ush provided at harvest needs to be
prolonged for extra cleaning. Before changing this setting, contact Hoshizaki Technical
Support at 1-800-233-1940 for recommendations. Keep in mind that setting the harvest
timer to a longer setting decreases 24-hour production.
Note that the pump-out timer (S4dip switch 3 & 4) acts in place of the harvest timer
during cycles with a pump-out. For details, see "II.C.3.c) Pump-Out Timer (S4 dip switch
3 & 4)."
Dip Switch Setting
Time (seconds)
No. 1
No. 2
OFF
OFF 60
ON
OFF 90
OFF
ON 120
ON
ON 180
1 2 3 4 5
ON
1 2 3 4 5 6 7 8 9 10
ON
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Harvest Pump Timer (7) (Do not adjust)
Factory Use (8)
S4 Dip Switch
Do Not Adjust
S5 Dip Switch
Rell Counter
(2 through 5)
Float Switch
Selector (1)