h) Float Switch Selector (S5 dip switch 1)
NOTICE
Do not adjust. This must be left in the factory default position or the icemaker will
not operate correctly.
On icemakers with a double oat switch, the oat switch selector determines which oat
switch (upper or lower) the control board monitors for rell initiation during the freeze
cycle, and the rell counter (S5 dip switch 2 through 5) determines the number of rells.
The KMS-1401MLJ uses a single oat switch with a double oat switch, upper oat
switch rell initiation oat switch selector setting and is set for 1 rell. When the freeze
cycle starts, the control board monitors the upper oat switch. If an upper oat switch
exists, rell is initiated by an open upper oat switch and is terminated by a closed upper
oat switch. There is a maximum rell time of 1 minute. In a single oat switch application
with a double oat switch setting, no upper oat switch exists, therefore the control board
reads an open upper oat switch immediately when the freeze cycle starts and initiates
a rell. Since there is no upper oat switch to close and terminate the rell, the rell lasts
for the maximum 1-minute. During the 1-minute rell, LED 4 is on.
S5 Dip Switch Setting
Float Switch Type
Rell Initiation with
Double Float Switch
No. 1
OFF Single or Double Lower Float Switch
ON Double Upper Float Switch
i) Rell Counter (S5 dip switch 2 through 5)
NOTICE
Do not adjust. These must be left in the factory default position or the icemaker will
not operate correctly.
Factory set. S5 dip switch 2 through 5 allows for rells during the freeze cycle.
The KMS-1401MLJ is factory set for 1 rell. Do not adjust.
S5 Dip Switch Setting
No. of Rells
No. 2 No. 3 No.4 No. 5
ON OFF OFF OFF 1 Rell
Note: When rell set > 0, water valve is off during pump-out even if S4 dip switch 3 & 4
are set to 3 off and 4 on. See "II.C.3.c) Pump-Out Timer (S4 dip switch 3 & 4)."