Hoshizaki DCM-500BWH Ice Maker User Manual


 
32
D. Sequence of Electrical Circuit – Dispensing
1. Continuous Dispense
Agitating motor energizes for .6 seconds for every 12 seconds of accumulative dispense
time. Maximum dispense time per dispense switch activation is 60 seconds. After
60 seconds, the dispense switch must be disengaged and engaged again.
BK BLACK O ORANGE W/BK WHITE/BLACK
BR BROWN P PINK W/BR WHITE/BROWN
BU BLUE R RED W/BU WHITE/BLUE
DBU DARK BLUE V VIOLET W/O WHITE/ORANGE
GY GRAY W WHITE W/R WHITE/RED
LBU LIGHT BLUE Y YELLOW
WIRE COLOR CODE
(Control Board)
(Control Board)
DCM-500BAH-OS
DCM-500BWH-OS
DCM-500BAH