Hoshizaki DCM-500BWH Ice Maker User Manual


 
65
13) Move the control switch to the "OFF" position, then turn off the power supply.
14) Close the water supply line shut-off valve.
c) Sanitizing Solution
Dilute 0.82 . oz. (25 ml) of a 5.25% sodium hypochlorite solution (chlorine bleach) with
1.6 gal. (6.0 l) of warm water.
d) Sanitizing Procedure - Following Cleaning Procedure
1) Make sure the control switch is in the "OFF" position, the power supply is off, and the
water supply line shut-off valve is closed.
2) Remove the front and top panels, then move the power switch to the "OFF" position.
3) Remove the front cover of the storage bin. Remove spout B, then remove spout A.
4) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to overow into the drain pan.
5) Replace spout A, spout B, and the front cover of the storage bin in their correct
positions.
6) Allow the icemaker to sit for about 10 minutes before operation.
7) Move the power switch to the "ON" position and replace the panels in their correct
positions. Turn on the power supply, then move the control switch to the "ICE" position.
Make ice using the solution until the icemaker stops making ice.
8) Move the control switch to the "DRAIN" position and allow the solution to drain for
5 minutes.
9) Move the control switch to the "ICE" position. Open the water supply line shut-off valve
to supply water to the reservoir.
10) After the gear motor starts, move the control switch to the "DRAIN" position and allow
the water system to drain for 5 minutes.
11) Move the control switch to the "ICE" position to start the automatic icemaking process.
Allow the icemaker to run for about 30 minutes, then clean and sanitize the dispensing
components as outlined below.
2. Dispensing Components
Perform after cleaning and sanitizing the water system as outlined above.
a) Cleaning Solution
Dilute 9.6 . oz. (0.29 l) of recommended cleaner, Hoshizaki "Scale Away" with 1.6 gal.
(6.0 l) of warm water.
b) Sanitizing Solution
Dilute 0.82 . oz. (25 ml) of a 5.25% sodium hypochlorite solution (chlorine bleach) with
1.6 gal. (6.0 l) of warm water.
c) Cleaning and Sanitizing Procedure
1) Move the control switch to the "OFF" position, then turn off the power supply.
2) Remove the front and top panels, then move the power switch to the "OFF" position.