Hoshizaki JWE-620UA-6B Dishwasher User Manual


 
22
21 Total Operation Cycles Before
Alert
10 to 990 cycles 1 to 99 2
(20 cycles)
22 Display Hold Function ON: stays on
OFF: goes off after 10 minutes
on or oF oF
23 Power Supply Lock Function ON: "Ch" keeps ashing until
electrode is turned off
OFF: "Ch" goes off when "ON/
OFF" button is switched off
on or oF oF
24 N/A
25 N/A
26
through
30
Error Log
Note: To erase the log, press
and hold the up and down
buttons for 3 seconds with one
of the error codes displayed.
The unit beeps once and the
entire log clears.
NA Most Recent
Errors
26 is most
recent.
"--" is displayed
if the log is
empty.
NA
8. Temperature Display
• Indicates the average water temperature read by the wash tank or internal booster tank
thermistor. Indicates wash tank water temperature in wash cycle, rinse (internal booster tank)
water temperature in rinse cycle. Press the down button to indicate rinse (internal booster
tank) water temperature instead of wash tank water temperature while the dishwasher is in
"READY" mode. To change the normal temperature display to the rinse (internal booster
tank) water temperature, see "Water Temperature Display" (service menu item 12) in "II.
D.7.b) Service Menu Chart."
• The temperature display range is 32°F to 199°F (0°C to 99°C). To change the display
scale, see "Temperature Display Scale" (service menu item 13) in "II.D.7.b) Service Menu
Chart."
• The temperature display updates every 30 seconds for the wash tank and every 5 seconds
for the internal booster tank.