f) Wash Tank Thermistor Error (H1, H2)
• If the wash tank thermistor senses a temperature at or above 231°F (111°C) (2.4kΩ), the
thermistor leads are considered shorted and the wash tank heaters de-energize, "H1"
appears in the display, and the buzzer sounds.
• If the wash tank thermistor senses a temperature at or below -6°F (-21°C) (517kΩ), the
thermistor leads are considered open and the wash tank heaters de-energize, "H2" appears
in the display, and the buzzer sounds.
• After replacing the failed component, the alarm resets.
• See the chart below for possible causes and remedies.
Note: When this error occurs, the auto ll cycle will not start.
Note: See “III.E. Thermistor Check” and “IV.M. Removal and Replacement of Thermistor.”
Control Board
Connector not properly
connected.
Reconnect.
Thermistor
Connector not properly
connected.
Reconnect.
Open circuit (H2). Replace.
Thermistor senses abnormal temperature.
H 1 / H 2
Code Error
Item Possible Cause Remedy
Continues (wash tank
heater off).
Operation
Short circuit (H1). Replace.
Defective. Replace.
Defective. Replace.