Hoshizaki KM-1601SWH/3 Ice Maker User Manual


 
10
5. KM-1601SRH with URC-21F (remote air-cooled) (auxiliary codes: R-0; R-1; some S-1)
This data applies to units with an 8 l/min water valve. The 8 l/min water valve is part
number 3U0111-02 and has J248-032 stamped on the side of the valve facing the rear of
the unit.
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE 12.8 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY 20 A
MAXIMUM FUSE SIZE 20 A
APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 *1583 (718) 1550 (703) 1435 (651)
Reference without *marks 80 1558 (707) 1507 (684) 1353 (614)
90 1550 (703) *1472 (668) 1332 (604)
100 1503 (682) 1439 (653) 1203 (546)
SHAPE OF ICE Crescent Cube
ICE PRODUCTION PER CYCLE 29.4 lbs. (13.3 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITY N/A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 2640(4.3) 2440(3.7)
WATER gal./24HR (gal./100 lbs.) 255(17.3) 503(31.8)
EXTERIOR DIMENSIONS (WxDxH) 48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear)
WEIGHT Net 275 lbs. (125 kg), Shipping 350 lbs. (159 kg)
CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT
- CONDENSATE DRAIN 3/8" OD Tube
CUBE CONTROL SYSTEM Float Switch
HARVESTING CONTROL SYSTEM Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL Timer Controlled. Overflow Pipe
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model CS18K6E-PFV
CONDENSER Air-Cooled Remote, Condenser Unit URC-21F
EVAPORATOR Vertical type, Stainless Steel and Copper
REFRIGERANT CONTROL Thermostatic Expansion Valve
Condensing Pressure Regulator on URC-21F
REFRIGERANT CHARGE R404A, 24 lb. 14.6 oz. (11300g)
(Icemaker 15 lb. 3.4 oz. Cond. Unit 9 lb. 11.2 oz.)
DESIGN PRESSURE High 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-out ( Internal )
COMPRESSOR PROTECTION Auto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW WATER PROTECTION Float Switch
ACCESSORIES -SUPPLIED N/A
-REQUIRED Ice Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONS VOLTAGE RANGE 187 - 253 V
AMBIENT TEMP. 45 -100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG