b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts when the thermistor reads 48°F (9°C) at the evaporator outlet
and the control board reads the thermistor's 3.9 kΩ signal. The harvest timer is factory
set, and generally no adjustment is required. However, a setting longer than the factory
setting may be advised in cases where the ush provided at harvest needs to be
prolonged for extra cleaning. Before changing this setting, contact Hoshizaki Technical
Support at 1-800-233-1940 for recommendations. Keep in mind that setting the harvest
timer to a longer setting decreases 24-hour production.
Note that the pump-out timer (S4 dip switch 3 & 4) acts in place of the harvest timer
during cycles with a pump-out. For details, see "II.C.3.c) Pump-Out Timer (S4 dip switch
3 & 4)."
S4 Dip Switch Setting Time
(seconds)
No. 1 No. 2
OFF OFF 60
ON OFF 90
OFF ON 120
ON ON 180
c) Pump-Out Timer (S4 dip switch 3 & 4)
CAUTION
Do not adjust S4 dip switch 3 off and S4 dip switch 4 on for KM-1601SAH/3.
Otherwise, pump motor does not rotate in the pump-out direction.
When a pump-out is called for, the pump motor stops after the preceding freeze cycle.
The pump motor restarts 2 seconds later in the reverse direction, taking water from the
bottom of the water tank and forcing pressure against the pump-out check valve seat
allowing water to go through the pump-out check valve and down the drain. At the same
time, water ows through the small tube to power ush the oat switch. The pump motor
drains the water tank for the time determined by the pump-out timer. The pump-out timer
also acts in place of the harvest timer during cycles with a pump-out. The pump-out timer
is factory set, and generally no adjustment is required. The pump-out timer control can
be set to pump-out for 10 or 20 seconds.
S4 Dip Switch Setting Time (seconds)
Inlet
Water
Valve
No. 3 No. 4
T1
T2
OFF OFF 10 150 closed
ON OFF 10 180 closed
OFF ON 10 120 open
ON ON 20 180 closed
T1: Time to drain the water tank
T2: Harvest timer at pump-out