Hoshizaki KM-1601SWH/3 Ice Maker User Manual


 
24
(5) Harvest Cycle
Same as the initial harvest cycle. See "II.B.1.b)(2) Initial Harvest Cycle."
Note: Unit continues to cycle until TBC is satised or power is turned off. The unit always
restarts at the 1-minute ll cycle.
(6) Shutdown
When ice contacts TBC bulb (TBC switch open), TBC shuts down the unit within
10 seconds. TBC is factory set, and generally no adjustment is required. However,
adjustment may be needed in some conditions, particularly at higher altitude locations.
CAUTION! Do not adjust S4 dip switch 7 out of the factory default position on this
model. This dip switch must be left in the factory default position or this unit will
not operate correctly.
Legend: CB–control board; Comp–compressor; FMR–fan motor-remote; F/S–oat switch;
HGV–hot gas valve; LLV–liquid line valve; PM–pump motor; TBC–thermostatic bin
control; WV–inlet water valve