Hoshizaki KM-1601SWH/3 Ice Maker User Manual


 
32
3. Controls and Adjustments
CAUTION
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact
Hoshizaki Technical Support at 1-800-233-1940.
a) Default Dip Switch Settings
Note that the settings vary for KM-1601SRH/3 depending on the water valve installed.
The dip switches are factory set to the following positions:
S4 Dip Switch
Model
Auxiliary
Code
Water
Valve Part
Number
Code on
Water
Valve
S4 Dip Switch No.
1 2 3 4 5 6 7 8 9 10
KM-1601SAH/3
"G" Control Board
Dip switch settings for air-cooled units
are as listed, regardless of auxiliary
code.
OFF OFF ON ON ON ON ON OFF OFF OFF
KM-1601SWH/3
"E" Control Board
Dip switch settings for water-cooled
units are as listed, regardless of
auxiliary code.
OFF OFF OFF OFF ON ON OFF OFF OFF ON
KM-1601SRH/3
"E" Control Board
R-0, R-1,
some S-1
3U0111-02
(8 l/min)
J248-032
ON OFF ON OFF OFF OFF OFF OFF OFF OFF
Some S-1 3U0111-01
(15 l/min)
J248-030
ON OFF OFF OFF ON ON OFF OFF OFF OFF
S-2 & later 4A1176-04 (11 l/min)
V-1 (M) & later 4A5251-04 (11 l/min)
S5 Dip Switch (Do Not Adjust)
Model
S5 Dip Switch No.
1 2 3 4 5
KM-1601SAH/3 OFF OFF OFF OFF OFF
KM-1601SWH/3
Not Applicable
KM-1601SRH/3
1 2 3 4 5 6 7 8 9 10
ON
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Factory Use (8)
S4 Dip Switch
All Models
Harvest Pump Timer (7) KM-1601SAH/3 "G" Control Board
Bin Control Selector (7) KM-1601SWH/3 & KM-1601SRH/3
"E" Control Board
1 2 3 4 5
ON
Float Switch Selector (1)
Rell Counter (2 through 5)
S5 Dip Switch
KM-1601SAH/3 "G" Control Board