hussman SCSS Cookware User Manual


 
IGSSB-SCSS / SCSS-SL-0108
18
Date:
Project Title:
Drawing No.:Drawn By:
Assembly: Drawing Title:
Date:
Hussmann Corporation, Int'l.
13770 Ramona Avenue
Chino, CA. 91710
(909)-590-4910 Lic.#: 644406
Revisions:
No. Description: Checked By:
By:
File Location:
Boris Kasrel
BJK
Sheet of
H:\WiringSchematics\In-Work\...
495-01-... / 880...
03.30.01
W8100003mnl.
Refrigerated Low Temp Self-Service Display
SCSS-L-E-S/C, Self-Contained, Electrical Defrost Wiring Diagram
1
1
~115V
~208/230V
MMM M
Anti-Sweat Htr 85W ~115V
Evaporator
Glass Htr 60W ~115V
(2) ~208/230V Finned Defrost Htr
J-Box, SCSS-L-E-S/C, Low Temp, Self-Contained, ElectricalDefrost
Legend:
controls lines
12 orange
12 black
12 orange
12 black
12 black
12 white
12 green
EKC 201 ~12V
12
14
13
15
16
17
8
9
10
11
2
4
1
3
7
5
6
Temp Probe
Defrost Termination
Temp Probe
Evap Temp
High/Low
Pressure Safety
~208/230-1Ph
Condensing Unit
2
3
45
67
~115V
~12V
Condensation Pan ~115V
12 black
12 black
12 orange
12green
12 orange
12 black
12 black
Transformer
12 black-hot
12 black
Compressor
Heaters
12green
12 black
12green
12 black
12 white
12 white
12 white