Cornelius 2 Flavor Juicer User Manual


 
Quest Juice Training Manual
Publication Number: TP00968 - 6 - © 2004, IMI Cornelius Inc.
CONCENTRATE HANDLING & LOADING
It is recommended that the concentrate be thawed in a refrigerated 35°F-40°F (1.6°C-4.4°C) compart-
ment for a minimum of 48 hours prior to loading into the Quest Juice Dispenser.
WARNING: Concentrate must be completely thawed and within the temperature range of 35°F-
40°F (1.6°C-4.4°C) prior to loading. Failing to supply concentrate inside the recommended tem-
perature range, especially below 35°F (1.6°C), will cause an out of brix drink (refer to the Brixing
Procedure section for details).
LOADING CONCENTRATE
The Quest Juice Dispenser is designed to use either disposable juice concentrate
containers or the optional Cornelius generic refillable container sold separately.
1.Thoroughly shake thawed concentrate prior to use.
2.Place concentrate containers on the dispensing platform shelf inside the refriger-
ated cabinet.
3.Engage the concentrate container by pressing it downward into the bottle adapter
opening on the dispensing platform.
NOTE: Be sure to lubricate the o-ring seal on the container nozzle. This will ensure a good seal
and allow the pumps to draw concentrated from the containers more easily. Failure to create a
good seal at this connection may result in weak drinks and/or seepage of concentrate.
4.Prime each pump by closing the cabinet door and press each dispense button until concentrate flows
from the dispense nozzles.
CHANGING CONCENTRATE CONTAINERS:
1.Open the cabinet door and move the valve handle from “Dispense” to “Flush”
2.Close the door. Depress and hold the dispense button until clear water flows from the dispense noz-
zle.
3.Open the cabinet door and return the handle to “Dispense”.
4.Depress and hold the dispense button for 1-2 seconds. This will relieve water pressure from the con-
centrate pump system.
5.Load concentrate container (see Loading Concentrate).