Cornelius 2 Flavor Juicer User Manual


 
Quest Juice Training Manual
Publication Number: TP00968 - 10 - © 2004, IMI Cornelius Inc.
Step 2 - Sanitize Pump System
1. Fill a clean concentrate container with 2 quarts (1.9L) of fresh sanitizing solution.
2. Place handles in the “dispense” position and close the door.
3. Press and hold the dispense button for 90 seconds then stop. Allow sanitizing solution to remain in
the lines for 5 minutes.
4. After 5 minutes, dispense the remaining sanitizing solution.
Step 3 - Prepare Dispenser for Use
1. Replace sanitizing solution container with a concentrate container and close the door.
2. Press and hold the dispense button until juice appears from the nozzle. Next dispense and discard
at least two 8 oz. (236.6ML) cups of juice in order to prime the system and prepare it for operation.
SEMI-ANNUAL
CAUTION: The following procedures require removal of the dispenser side panel(s). Disconnect
the power cord from the receptacle prior to proceeding.
Clean Water Inlet Strainer:
1. Remove the right side panel from the dispenser.
2. Turn off the water supply to the dispenser.
3. Remove the access port from the “Y” shaped water inlet solenoid
located on the right side of the dispenser.
4. Clean and reinstall the stainless steel water strainer.
Clean Chassis Interior:
1. Clean the condenser cooling fins.
2. Clean the air inlet grilles located on the rear and top panels of the dis-
penser.
3. Clean the interior base.
4. Wipe the fan blade clean.
5. Reinstall the right side panel, turn on the water supply, and plug the dispenser into the power recep-
tacle.
Check and Top-Off Water Ice Bath:
1. Remove the drip tray and lower splash panel.
2. If the Ice bath level is below the “Full” indicator, top it off with water. Refer to the Filling the Ice Bath
procedure in the Installation section of this manual.