REMOVAL OF THE AGITATOR MOTOR
REMOVAL OF THE REFRIGERATION CHASSIS
1.Remove the thumbscrew located at the rear
of the motor before removing the agitator
motor.
2.Lift the motor out of the ice bath. Disconnect
the wire lead from the ice bank control.
Note: You will have to feed the water tubes through
the refrigeration frame to completely remove.
1.With the cabinet removed, remove (2) screws
from the lower front and (2) screws from the
lower rear of the water bath housing.
2.Unsnap the wire harnesses (red and white)
connectors from the bracket mounted to the
water bath cover.
2
1
3
4
1