Cornelius 2 Flavor Juicer User Manual


 
Quest Juice Training Manual
© 2004, IMI Cornelius Inc. - 31 - Publication Number: TP00968
Tip:
When re-assembling the large o-ring may be
pinched if not installed properly. Place the slide
valve into the bottom of the adaptor keeping
straight across. Press evenly to seat the o-ring.
It is not advisable to rotate the valve back and
forth in and attempt to seat the o-ring. Do the
same when installing the top.
When securing the screws do it in the X pattern
tightening the opposites across from each
other. Be sure the are fully tighten to prevent
leaking.
Bottle Adaptor - Sold Out Sensors
The sold-out sensors are located in the bottle
adaptor neck.
The do not get cleaned during normal flushing
procedures. They are cleaned only during sani-
tizing.
Be sure there is no build up of pulp or concen-
trate on the pins themselves. The results will be
an erratic operation of the refill lights.
Bottle Adaptor - Tray Grommets
When installing the grommets be sure that
each one is sealed below the lead in taper on
the top of the bottle adaptor.
TIP: Press the entire tray down evenly to seat
Run finger around the edge to seal.
1
3
2
4
Sold Out Contacts