Cornelius R-404A Beverage Dispenser User Manual


 
312030002 6
CONTROL PANEL DISPLAY MESSAGES
‘‘FILL 1’’ and ‘‘FILL 2’’ Fault Messages.
‘‘FILL 1’’ and ‘‘FILL 2’’ fault messages will appear on the message display only after the SYRUP PRIME
switches have been pressed and the syrup systems sold-out floats have been filled with product. ‘‘FILL 1’’ and
‘‘FILL 2’’ fault messages will continue to be displayed until the BLEND ON/OFF switches have been pressed to
fill the product blender tanks with product.
‘‘ERROR 1’’ and ‘‘ERROR 2’’ Fault Messages.
‘‘ERROR 1’’ and ‘‘ERROR 2’’ fault messages will appear on the message display only if an error within the Unit
has developed interrupting normal operation. Error will have to be located and corrected, then press the
‘‘ERROR RESET’’ to restore the Unit to normal operation. ‘‘ERROR 1’’ or ‘‘ERROR 2’’ fault message will disap-
pear from the display.
‘‘OFF 1’’ and ‘‘OFF 2’’ Fault Messages.
‘‘OFF 1’’ and ‘‘OFF 2’’ fault messages will appear on the message display when either freeze cylinder beater is
not operating.
‘‘H
2
O OUT’’ Fault Message.
The Unit plain water inlet system contains a water pressure switch. An H
2
O OUT fault message will appear on
the message display if the plain water source to the unit has been disrupted or if a water pressure drop should
occur. The Unit will continue to operate for 1-1/2 minutes after ‘‘H
2
O OUT’’ fault message has appeared. If the
water pressure has not been restored or the water pressure improved after 1-1/2 minutes, the Unit operation will
shut down. After plain water source has been restored or the water pressure has improved, the Unit will resume
its normal operation and the ‘‘H
2
O OUT’’ fault message will disappear from the message display.
‘‘CO
2
OUT’’ Fault Message.
‘‘CO
2
OUT’’ fault message will appear on the message display when CO
2
supply to the Unit has been turned off
or if the CO
2
pressure drops below 50-psi. A minimum CO
2
pressure of 75-psi must be available to the Unit to
extinguish the ‘‘CO
2
OUT’’ fault message.
‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ Fault Messages.
‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ fault messages will appear on the message display if the syrup supply is not con-
nected to the Unit syrup system or if the syrup supply is exhausted. The Unit syrup systems syrup float switches
must be filled with syrup to extinguish the ‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ fault messages.
‘‘DEFROST 1’’ or ‘‘DEFROST 2’’ Display Messages.
‘‘DEFROST 1’’ or ‘‘DEFROST 2’’ display messages will appear on the message display if either freeze cylinder
is in the defrost mode. ‘‘DEFROST 1’’ or ‘‘DEFROST 2’’ messages will remain on during the defrost cycle and
will disappear when the cycle has ended.
‘‘POINT OF SALE’’ Display Messages.
Three ‘‘POINT OF SALE‘’ display messages are available to choose from and may be programmed into the Unit
to appear on the message display. The POINT OF SALE display messages should be programmed into the
Unit electronics by a qualified Service Person.