Cornelius R-404A Beverage Dispenser User Manual


 
312030002 12
8. If freeze cylinder is not full of product, repeatedly pull and release the faceplate relief valve to slowly bleed
CO
2
from the freeze cylinder and allow product to fill the cylinder. Do not relieve freeze cylinder pressure
too fast or the product will foam excessively in the cylinder and lose carbonation.
BAGINBOX SYSTEM
1. Press applicable ‘‘OFF’’ switch on the control panel to stop the applicable freeze cylinder beater and refrig-
eration system.
2. Disconnect syrup outlet tube from empty bag-in-box container, then remove empty container.
3. Open flap on full bag-in-box container.
4. Pull bag-in-box container connector from the container, then remove dust cap from the connector.
5. Rinse syrup outlet tube in warm water.
6. Connect syrup outlet tube to full bag-in-box container. Make sure syrup outlet tube is securely connected to
the container.
7. Press applicable ‘‘SYRUP PRIME’’ switch to fill applicable No. 1 or No. 2 syrup system syrup float switch
with syrup.
8. Press applicable BLEND ON/OFF’’ switch to fill applicable No. 1 or No. 2 system product blender tank with
product.
9. Press applicable ‘‘ON’’ switch to start the refrigeration system and beater in applicable No. 1 or No. 2
freeze cylinder.
10. If freeze cylinder is not full of product, repeatedly pull and release the faceplate relief valve to slowly bleed
CO
2
from the freeze cylinder and allow product to fill the cylinder. Do not relieve freeze cylinder pressure
too fast or the product will foam excessively in the cylinder and lose carbonation.
SYRUP FLAVOR CHANGE
The Unit syrup system that the syrup flavor change will be made on must be sanitized before connecting new
flavor syrup to the system. It may be necessary to readjust BRIX (Water-To-Syrup) Ratio of the dispensed
product after making a syrup flavor change.
REPLENISHING CO
2
SUPPLY
The Unit and its syrup supply source may be connected to either a bulk CO
2
supply or to a CO
2
cylinder. If your
Unit is connected to a CO
2
cylinder, proceed as follows to replenish the CO
2
supply.
WARNING: CO
2
displaces oxygen. Strict attention must be observed in the prevention of
CO
2
(carbon dioxide) gas leaks in the entire CO
2
and soft drink system. If a CO
2
gas leak is
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
2
gas will experience
tremors which are followed rapidly by loss of consciousness and suffocation.
NOTE: When indicator on primary CO
2
cylinder regulator assembly 1800-psi gage is in shaded
(‘‘change CO
2
cylinder’’) portion of the dial, CO
2
cylinder is almost empty and should be changed.
1. Fully close (clockwise) CO
2
cylinder valve.
2. Slowly loosen CO
2
regulator assembly coupling nut allowing CO
2
pressure to escape, then remove regula-
tor assembly from empty CO
2
cylinder.