Cornelius R-404A Beverage Dispenser User Manual


 
31203000211
SECONDARY CO
2
REGULATORS
The secondary CO
2
regulators, located inside the Unit, control CO
2
pressure to the Unit carbonator(s) and the
product blender tanks. If adjustment of these CO
2
regulators should become necessary, call a qualified Service
Person to make the adjustments.
ADJUSTING BRIX (WATER-TO-SYRUP RATIO) OF DISPENSED PRODUCT
BRIX is the Water-to-Syrup Ratio of the dispensed product and should be periodically checked and if neces-
sary, be adjusted by a qualified Service Person.
REPLENISHING SYRUP SUPPLY
SYRUP TANKS SYSTEM
NOTE: Sugar-free diet syrup cannot be used with this Unit.
Although syrup replenishing can be done anytime, the syrup supply must be replenished when either the
‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ fault messages are displayed on the message display indicating either No. 1 or No. 2
syrup system syrup tank is empty.
NOTE: The following instructions are applicable only when replenishing the syrup supply. Refer to
SYRUP FLAVOR CHANGE when changing syrup flavors.
1. Press applicable ‘‘OFF’’ switch on the control panel to stop the applicable freeze cylinder beater and refrig-
eration system.
IMPORTANT: The following CO
2
and liquid disconnect and connecting procedure for the syrup tank
replacement or filling the syrup tank in place must be performed in the order as follows:
To disconnect syrup tank from the Unit syrup system.
First, disconnect liquid disconnect from the syrup tank. NOTE - Disconnecting the liquid quick dis-
connect from the syrup tank first prevents syrup from backflowing through the Unit syrup flow
regulator which may alter the regulator adjustment.
Second, disconnect CO
2
quick disconnect from the syrup tank.
To connect syrup tank into the Unit syrup system.
First, connect CO
2
quick disconnect to the syrup tank to pressurize the tank.
Second, connect liquid quick disconnect to the syrup tank.
2. Disconnect inlet (CO
2
) and outlet (syrup) lines from the empty syrup tank.
3. Check syrup tank quick disconnects for sticky or restricted operation. Rinse the disconnects in warm water.
4. First, pressurize the full syrup tank by connecting CO
2
line to the tank, then connect the Unit syrup inlet
line to the tank.
5. Press applicable ‘‘SYRUP PRIME’’ switch to fill applicable No. 1 or No. 2 syrup system syrup float switch
with syrup.
6. Press applicable BLEND ON/OFF’’ switch to fill applicable No. 1 or No. 2 system product blender tank with
product.
7. Press applicable ‘‘ON’’ switch to start the refrigeration system and beater in applicable No. 1 or No. 2
freeze cylinder.