JFT Series Technical Manual 7610-002-77-38
Issued: 03-16-2006 Revised: 09-14-2007
SECTION 1: SPECIFICATION INFORMATION
4
PERFORMANCE/CAPABILITIES OF THE JFT-S
OPERATING CAPACITY (RACKS/HOUR)
DISHES OR GLASSES PER HOUR (8.6 FPM) 17,101
DISHES OR GLASSES PER HOUR (6.4 FPM) 12,726
TANK CAPACITY (GALLONS):
PREWASH TANK 36
WASH TANK 36
POWER RINSE TANK 36
PUMP CAPACITY (GPM)
PREWASH PUMP 260
WASH PUMP 260
POWER RINSE PUMP 230
VENTING REQUIREMENTS (CFM)(100% CAP.)
FPM (INDIRECT) 1200
CONVEYOR SPEED (FPM) HIGH END 8.6
CONVEYOR SPEED (FPM) LOW END 6.4
WATER TEMPERATURES (
°
F)
PREWASH (RECOMMENDED) 140
WASH (MINIMUM) 152
POWER RINSE (MINIMUM) 161
FINAL RINSE (MINIMUM) 180
FLOW PRESSURE (PSI) 20±5
FLOWRATE (GPM) 2.3
STEAM BOOSTER REQUIREMENTS
Steam Input Rate (Minimum) 15 PSIG
Steam Input Rate (Maximum) 20 PSIG
Consumption @ 110
°
F Incoming Water Temp 145 lbs./hr.
Consumption WITH BLOWER DRYER 245 lbs./hr.
NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on
this page is for reference only and may be subject to change without notice.