Legend
1 - 1-1/2" NPT Machine Drain Connection
(Floor drain - optional to either end)
2 - Electrical Connection - See Table for Amp Draw
3 - 3/4" NPT Incoming Water Connection
4 - 1-1/2" NPT Steam Connection
5 - 3/4" NPT Wash Section Condensate Return
6 - 3/4" NPT Power Rinse Section Condensate Return
7 - 3/4" NPT Booster Heater Condensate Return
8 - Condensate Connection - See Detail
JFT Series Technical Manual 7610-002-77-38
Issued: 03-16-2006 Revised: 09-14-2007
SECTION 1: SPECIFICATION INFORMATION
JFT-S L-R & R-L LEGEND & EXHAUST FAN DIMENSIONS
9
Note:
The condensate removal system built into the dishmachine consists of a fan
that will remove 1200 CFM. A single condensate connection must be provided
by the installing contractor. This is an indirect connection that must be capable
of removing 1200 CFM from the area.
A.F.F.
Exhaust Requirements
- 1200 CFM
6'-10" [2083mm]
3" [72mm] Deep
18" [457mm] I.D. Square
Condensate duct pan mounted on top of
dishmachine electrical section.
Condensate Exhaust Duct
Minimum 18" Square (Cross Section 324 Sq. In.)
Provided by HVAC Contractor
Condensate duct to extended into duct pan.