Jackson JFT-S Dishwasher User Manual


 
Legend
1 - 1-1/2" NPT Machine Drain Connection
(Floor drain - optional to either end)
2 - *Wash Tank Electrical Connection
3 - *Rinse Tank Electrical Connection
4 - *Booster Heater Electrical Connection
5 - *Motor Controls Electrical Connection
6 - 3/4" NPT Incoming Water Connection
7 - Condensate Connection - See Detail
JFT Series Technical Manual 7610-002-77-38
Issued: 03-16-2006 Revised: 09-14-2007
SECTION 1: SPECIFICATION INFORMATION
JFT L-R & R-L LEGEND & EXHAUST FAN DIMENSIONS
6
Note:
The condensate removal system built into the dishmachine consists of a fan
that will remove 1200 CFM. A single condensate connection must be provided
by the installing contractor. This is an indirect connection that must be capable
of removing 1200 CFM from the area.
A.F.F.
Exhaust Requirements
- 1200 CFM
6'-10" [2083mm]
3" [72mm] Deep
18" [457mm] I.D. Square
Condensate duct pan mounted on top of
dishmachine electrical section.
Condensate Exhaust Duct
Minimum 18" Square (Cross Section 324 Sq. In.)
Provided by HVAC Contractor
Condensate duct to extended into duct pan.