Jackson JFT-S Dishwasher User Manual


 
JFT Series Technical Manual 7610-002-77-38
Issued: 03-16-2006 Revised: 09-14-2007
SECTION 1: SPECIFICATION INFORMATION
5
WASH/PREWASH PUMP MOTOR (2) 3 HP
POWER RINSE PUMP MOTOR (1) 2 HP
FINAL RINSE PUMP MOTOR (1) 1/2 HP
DRIVE MOTOR (1) 1/4 HP
EXHAUST FAN MOTOR (1) 0.31 KW
BLOWER DRYER MOTOR (1) 2.1 KW
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate
and meets all applicable national and local codes. These numbers are provided in this manual simply for reference
and may change without notice at any given time.
CONTROLS, MOTORS, & BLOWER DRYER SECTION
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOL
TS PH HZ RATINGS AMPS CIRCUIT
208 3 60 N/A 22 30 AMP
230 3 60 N/A 22 30 AMP
460 3 60 N/A 11 15 AMP
600 3 60 N/A 10 15 AMP
CONTROLS, MOTORS, (NO BLOWER DRYER SECTION)
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOLTS PH HZ RATINGS AMPS CIRCUIT
208 3 60 N/A 15 30 AMP
230 3 60 N/A 15 30 AMP
460 3 60 N/A 7 15 AMP
600 3 60 N/A 6 15 AMP
WASH/POWER RINSE SECTIONS (COMBINED)
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOL
TS PH HZ RATINGS AMPS CIRCUIT
208 3 60 N/A 16 20 AMP
230 3 60 N/A 16 20 AMP
460 3 60 N/A 8 15 AMP
600 3 60 N/A 7 15 AMP
ELECTRICAL REQUIREMENTS OF THE JFT-S