JFT Series Technical Manual 7610-002-77-38
Issued: 03-16-2006 Revised: 09-14-2007
SECTION 1: SPECIFICATION INFORMATION
2
OPERATING CAPACITY (RACKS/HOUR)
DISHES OR GLASSES PER HOUR (8.6 FPM) 17,101
DISHES OR GLASSES PER HOUR (6.4 FPM) 12, 726
TANK CAPACITY (GALLONS):
PREWASH TANK 36
WASH TANK 36
POWER RINSE TANK 36
PUMP CAPACITY (GPM)
PREWASH PUMP 260
WASH PUMP 260
POWER RINSE PUMP 230
VENTING REQUIREMENTS (CFM)(100% CAP.)
FPM (INDIRECT) 1200
CONVEYOR SPEED (FPM) HIGH END 8.6
CONVEYOR SPEED (FPM) LOW END 6.4
WATER TEMPERATURES (
°
F)
PREWASH (RECOMMENDED) 140
WASH (MINIMUM) 152
POWER RINSE (MINIMUM) 161
FINAL RINSE (MINIMUM) 180
FLOW PRESSURE (PSI) 20±5
FLOWRATE (GPM) 2.3
NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on
this page is for reference only and may be subject to change without notice.
WASH/PREWASH PUMP MOTOR (2) 3 HP
POWER RINSE PUMP MOTOR (1) 2 HP
FINAL RINSE PUMP MOTOR (1) 1/2 HP
DRIVE MOTOR (1) 1/4 HP
EXHAUST FAN MOTOR (1) 0.31 KW
BLOWER DRYER MOTOR (1) 2.1 KW
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate
and meets all applicable national and local codes. These numbers are provided in this manual simply for reference
and may change without notice at any given time.
PERFORMANCE/CAPABILITIES OF THE JFT