Keating Of Chicago 0107 Pasta Maker User Manual


 
12
PROBLEM PROBABLE CAUSE SOLUTION
Constant pilot won’t
light.
a.Gas isn't turned on.
b.Clogged constant pilot tubing.
c
.Constant pilot valve isn't turned on.
a.Turn manual gas valve on. If using
flexible connector with quick disconnect,
make sure quick disconnect is completely
engaged.
b.Turn Custom Pasta System and manual
gas valve off. Clean tubing.
c
.Turn constant pilot valve on and adjust
pilot flame height.
Runner pilot tube
won't light.
a.Gas isn't turned on.
b.No electricity to Custom Pasta System.
c.Clogged runner pilot orifice(s).
d.Pilot gas cock is on “OFF” position.
e.Drain valve handle isn’t pushed in
completely (Counter model only)
f. Gas valve is faulty.
g.Hi-Limit has been activated.
a.Turn manual gas valve on. If using
flexible connector with quick disconnect,
make sure quick disconnect is completely
engaged.
b.Plug Custom Pasta System into approved
outlet.
c.Turn Custom Pasta System and manual
gas valve off. Clean orifice(s) and other
parts as necessary.
d.Turn pilot gas cock to “ON” position.
e.Push in and latch drain valve handle to
activate rear drain safety switch.
f. Replace gas valve.
g.Push Hi-Limit reset button located under
control panel.
Runner pilot won’t
stay lit.
a.Low gas supply or pressure.
b.Dirty runner pilot tube or pilot.
c.Low pilot flame height.
d.Flame switch is faulty
e.Momentary switch is faulty.
f. Exhaust problems or drafts in kitchen.
g.Delayed ignition.
a.Verify if size of incoming gas line to
Custom Pasta System and manifold gas
pressure is adequate.
b.Turn Custom pasta System and manual
gas valve orifice(s) off. Clean orifice(s)
and pilot tube.
c.Verify if size of incoming gas line to
Custom Pasta System and manifold gas
pressure is adequate.
d.If it takes more than 30 seconds for pilot
to stay lit, reposition or replace flame
switch.
e.Replace momentary switch.
f. Install or adjust flue restrictors. If problem
persists, contact your HVAC
represent
ative.
g.See diagnosis below.
Delayed ignition. a.Dirty runner pilot tube or pilot.
b.Low pilot flame height.
c.Exhaust problems or drafts in kitchen.
d.Low gas supply or pressure.
a.Turn Custom pasta System and manual
gas valve orifice(s) off. Clean orifice(s)
and pilot tube.
b.Verify proper incoming gas pressure.
c.Install or adjust flue restrictors. If problem
persists, contact your HVAC
representative.
d.
Verify if size of incoming gas line to
Custom Pasta System
Flames come out top
of flue.
a.Excessive gas supply or pressure.
b.Collapsed burner radiants.
c,Exhaust problems.
a.Adjust pressure, change burner orifices
or inst
all in-line regulator
.
b.Replace radiants.
c.Install or adjust flue restrictors. If problem
persist
s, cont
act your HVAC
representative.