Kenmore 73819 Range User Manual


 
NORMAL INSTALLATION STEPS
Provide Adequate Gas Supply
The range is designed to operate at a pressure of 4
inches of water column on natural gas or, if designed
for LP gas (propane or butane), 10 inches of water
column. Make sure the range is supplied with the type
of gas for which it is designed If, at any time in the
future, the range is to be supplied with a different type
of gas, conversion adjustments must be made by a
qualified service technician before attempting to oper-
ate the range on that gas.
For proper operation, the pressure of natural gas sup-
plied to the regulator must be between 4 and 13 inch-
es of water column For LP gas, the pressure supplied
must be between 10 and 13 inches of water column
When checking for proper operation of the regulator,
the inlet pressure must be at least t inch greater than
the operating (manifold) pressure as given above. The
pressure regulator located at the inlet of the range
manifold must remain in the supply fine regardless of
whether natural or LP gas is being used A flexible
metal appliance connector used to connect the range
to the gas supply line should have an tDo of 1/2" and
be 5 feet in length (shorter and longer lengths are
acceptable) for ease of installation
2
Connect the Range to Gas
Before disconnecting the old range, shut off the main
gas supply valve and leave it off until new hook-up
has been completed
Because hard piping restricts movement of the range,
the use of an AoG.A.-certified flexible metal appliance
connector is recommended unless local codes require
a hard-piped connection Never use an old connector
when installing a new range
To prevent gas leaks, wrap pipe thread tape with
Teflon* around, or put pipe joint compound on, a!l
male (external) pipe threads
"Teflon: Registered trademark of DuPont
Gas Pipe and Electric Outlet Locations:
for t20V outlet on
rear waif and area
ler thru the wall con-
nection of pipe stub
and shut-off valve
Recommc _
for thru tile floor con-
nection of pipe stub
/
and shut-off valve .
Flexible Connector Hookup Rigid Pipe Hookup
Pressure Regulator
"_ _L, Adapter4-_ "_ Nipp,e Adapter4J '_ 90"
. Elbow
Gas F1ow
tale Range _ -_lll
Manifold Pipe Flex Connector Adapter
Adapter _ Nipple
Gassh°"°'va've-- 'kl J
Installer: _nform the consumer _ Ill 1/2" or 3_,, _ lit
of the local!on of the gas Gas i e---._
shut-off valve _ P p "_ _
1. Install a manual gas line shut-off valve in the gas
line in an easily accessed location outside of the
range Make sure everyone operating the range
knows where and how to shut off the gas supply to the
range,
2. Install male 1/2" flare union adapter to the 1/2" NPT
internal thread at inlet of pressure regulator.
3. Install male I/2" or 3/4" flare union adapter to the
NPT internal thread of the manual shut-off valve, tak-
ing care to back up the shut-off valve to keep it from
turning
4. Connect flexible metal appliance connector to the
adapter on the range. Position range to permit con-
nection at the shut-off valve
(continued next page)
5