Miele 10 118 580 Ventilation Hood User Manual


 
Description of functions
15
Con@ctivity 2.0 function
Automatic control
This hood features a communication
fun
ction which enables the automatic
control of the hood based on the
operational status of a Miele induction
cooktop.
To enable the communication function,
the cooktop must be equipped with the
corresponding Con@ctivity 2.0 stick .
Please refer to the installation
instructions for the Con@ctivity 2.0
stick t
o determine whether connection
to your cooktop is possible.
There must be radio contact between
the coo
ktop and the hood for you to be
able to use the Con@ctivity 2.0 function
(see "Activating Con@ctivity 2.0").
The cooktop transmits information
about its oper
ational status to the hood
using a radio signal.
When a burner is turned on, the
coo
ktop lighting on the hood turns
on automatically. After a brief delay,
the ventilation hood fan also comes
on.
During cooking, the hood
automatically selects the fan level
based on the number of burners in
operation and their power levels.
Once you have turned off the
coo
ktop, the fan and the lighting will
turn off automatically after a
predetermined delay.
Detailed information about this function
can be found under "Operation."