Miele 10 118 580 Ventilation Hood User Manual


 
Electrical connection
44
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
All electrical work should be
per
formed by a qualified electrician
in strict accordance with national
regulations (for USA: ANSI-NFPA 70)
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous.
Ensure that power to the appliance is
OFF whil
e installation or repair work
is performed.
Verify that the voltage, load and
cir
cuit rating information found on
the data plate (located behind the
baffle filters), match the household
electrical supply before installing the
hood.
Use only with ventilation hood cord-
connection kits that have been
in
vestigated and found acceptable
for use with this model hood.
If there is any question concerning
the electrical connection of this
applianc
e to your power supply,
please consult a licensed electrician
or call Miele’s Technical Service
Department.
WARNING: THIS APPLIANCE MUST
BE GROUNDED
Grounding Instructions
WARNING - Improper grounding can
r
esult in a risk of electric shock.
This appliance must be grounded. In
the even
t of an electrical short
circuit, grounding reduces the risk of
electric shock by providing a path of
least resistance.plug.
If there is any doubt, have the
electrical system of the house
checked by a qualified electrician.
To increase security before the
machine is installed, it is
r
ecommended to install a protective
switch (30 mA).
The
hood must be hard wired
accordingly:
Black/Red wire: connect to L1 (live)
White wire: connect to N (neutral)
Green wire: connect to GND (ground)