4.9 Spray Arms
The circulation pump (M6) moves the wash water from the sump
through the Filter Assembly and to the Spray Arms. The water
pressure causes a propulsion effect causing the Spray Arms to rotate.
4.9.1 Spray Arms - Rotation Data
Top Spray Arm: 30 to 55 rpm
Middle Spray Arm: 16 to 40 rpm
Bottom Spray Arm: 24 to 50 rpm
4.10 Filter Assembly
1 Coarse Filter / Handle
2 Large Surface Area Fine Filter
3 Microfine ilter F
4 Filter cap
Figure 4-5: Filter Assembly
Circulating wash water is filtered via 2 parallel paths. A portion of the
water flows through the center opening of the Coarse Filter and
passes through the Microfine Filter. The remaining water passes
through the Large Surface Area Fine Filter. The Coarse Filter, is
attached to the Filter Combination Handle. If dispensed powder
31