Miele G800 Dishwasher User Manual


 
Technical Information
G600 & G800 Electronic Dishwashers
5.41 Top Solo Valve - Removal
1. Remove the Circulation Pump (5.35).
2. Disconnect the Electrical Connection.
Warning
It is essential to note correct position of the Valve before removal.
(The direction of flow is marked by an arrow on the Valve Housing)
3. Pull the valve away from the circulation pump.
Top Solo Valve
Figure 5-35: Circulation Pump with Top Solo Valve attached.
Service Tip
During re-installation of the Top Solo Valve ensure the cutout on the
Valve Housing engages with the lug on the Circulation Pump
Housing.
90