Technical Information
G600 & G800 Electronic Dishwashers
5.42 Overflow Level Switch - Removal
Refer to figure 5-36
1. Remove as much water as possible from the Sump.
2. Remove the Cover Plate (5.5)
3. Locate the Overflow Level Switch mounted on the right / rear side
of the Connecting Strip.
4. Press the Retaining Clips toward each other (A); push in to release
it from the frame(B).
5. Disconnect the Electrical Connection and Hose.
A
B
A
Figure 5-36: Releasing the Overflow Level Switch from the Connecting Strip
91