Mitsubishi Electronics 882.00273.00 Blender User Manual


 
Three (3) types of recipe entry procedures available:
o Quickset mode (up to 6-component) recipe entry. Color and additives are
metered as a percentage of the virgin material.
o Percentage mode recipe entry. Ingredients are metered as a percentage of
the overall batch.
o Parts mode recipe entry (i.e. 500:1) Ingredients are metered as a ratio to
each other within the batch
Full control diagnostics
Serial printer and RS-485 communications ports
System Component Description
This section describes the various components of the blending system.
Supply Hoppers
The material supply hoppers are located on top of the blender frame. These hoppers store a
supply of material for the individual metering devices. They are sized based on the total
throughput of the blender.
The blending system does not include any level indication devices on the unit. Optional low-
level sensors are available. The blender controller will
alarm if it runs out of material while
trying to make a batch, but low-level sensors will alert floor personnel to the problem sooner.
Each hopper is equipped with a sight glass and/or access door.
Figure 5: Typical Hopper Assembly
BF1-615.3 Chapter 2: 1BFunctional Description 16 of 101