Mitsubishi Electronics fre700 Microwave Oven User Manual


 
26
PARAMETER LIST
58 Restart cushion time 0 to 60s 1s
59 Remote function selection 0, 1, 2, 3 0
60
Energy saving control
selection
0, 9 0
61 Reference current
0 to 500A,
9999
9999
62
Reference value at
acceleration
0 to 200%,
9999
9999
63
Reference value at
deceleration
0 to 200%,
9999
9999
65 Retry selection 0 to 5 0
66
Stall prevention operation
reduction starting frequency
0 to 400Hz 60Hz
67
Number of retries at fault
occurrence
0 to 10, 101
to 110
0
68 Retry waiting time 0.1 to 360s 1s
69 Retry count display erase 0 0
70
Special regenerative brake
duty
0 to 30% 0%
71 Applied motor
0, 1, 3 to 6,
13 to 16, 23,
24, 40, 43,
44, 50, 53,
54
0
72 PWM frequency selection 0 to 15 1
73, 74 Parameter for manufacturer setting. Do not set.
75
Reset selection/PU stop
selection
0 to 3, 14 to
17
14
77 ∗6 Parameter write selection 0, 1, 2 0
78
Reverse rotation prevention
selection
0, 1, 2 0
79 ∗9 Operation mode selection
0, 1, 2, 3, 4,
6, 7
0
80 Motor capacity
0.1 to 15kW,
9999
9999
81 Number of motor poles
2, 4, 6, 8, 10,
9999
9999
82 Motor excitation current
0 to 500A
(0 to ****),
9999
∗5
9999
83 Rated motor voltage 0 to 1000V
200V/
400V
∗4
84 Rated motor frequency 10 to 120Hz 60Hz
89
Speed control gain (Advanced
magnetic flux vector)
0 to 200%,
9999
9999
90 Motor constant (R1)
0 to 50Ω
(0 to ****),
9999
∗5
9999
91 Motor constant (R2)
0 to 50Ω
(0 to ****),
9999
∗5
9999
92 Motor constant (L1)
0 to 1000mH
(0 to 50
Ω
, 0 to
****), 9999
∗5
9999
93 Motor constant (L2)
0 to 1000mH
(0 to 50
Ω
, 0 to
****), 9999
∗5
9999
94 Motor constant (X)
0 to 100%
(0 to 50
, 0
to ****), 9999
∗5
9999
96 Auto tuning setting/status 0, 1, 11, 21 0
Parameter
Name
Setting
Range
Initial
Value
117 to 124
Parameter for manufacturer setting. Do not set.
125
Frequency setting gain
frequency
0 to 400Hz 60Hz
126 Parameter for manufacturer setting. Do not set.
127
PID control automatic
switchover frequency
0 to 400Hz,
9999
9999
128 PID action selection
0, 20, 21,
40 to 43, 50,
51, 60, 61
0
129 PID proportional band
0.1 to 1000%,
9999
100%
130 PID integral time
0.1 to 3600s,
9999
1s
131 PID upper limit
0 to 100%,
9999
9999
132 PID lower limit
0 to 100%,
9999
9999
133 Parameter for manufacturer setting. Do not set.
134 PID differential time
0.01 to 10.00s,
9999
9999
145, 146 Parameter for manufacturer setting. Do not set.
147
Acceleration/deceleration time
switching frequency
0 to 400Hz,
9999
9999
150 Output current detection level 0 to 200% 150%
151
Output current detection signal
delay time
0 to 10s 0s
152 Zero current detection level 0 to 200% 5%
153 Zero current detection time 0 to 1s 0.5s
156
Stall prevention operation
selection
0 to 31, 100,
101
0
157 OL signal output timer
0 to 25s,
9999
0s
160 User group read selection 0, 1, 9999 0
161
Frequency setting/key lock
operation selection
0, 1, 10, 11 0
162
Automatic restart after
instantaneous power failure
selection
0, 1, 10, 11 1
165
Stall prevention operation level
for restart
0 to 200% 150%
168, 169 Parameter for manufacturer setting. Do not set.
170 Watt-hour meter clear 0, 10, 9999 9999
171 Operation hour meter clear 0, 9999 9999
172
User group registered display/
batch clear
9999, (0 to
16)
0
173 User group registration
0 to 999,
9999
9999
174 User group clear
0 to 999,
9999
9999
178, 179 Parameter for manufacturer setting. Do not set.
180 RY4 function selection
0 to 5, 7, 8,
10, 12,
14 to 16, 18,
24, 25, 62,
65 to 67,
9999
0
181 RY3 function selection 1
182 RY2 function selection 2
183 RY9 function selection 24
184 RYB function selection 62
Parameter
Name
Setting
Range
Initial
Value