PARAMETER LIST
313 RX9 function selection
0, 1, 3, 4, 7, 8,
11 to 16, 20,
25, 26, 46, 47,
64, 68, 80, 81,
90, 91, 93, 95,
96, 98, 99,
100, 101, 103,
104, 107, 108,
111 to 116,
120, 125, 126,
146, 147, 164,
168, 180, 181,
190, 191, 193,
195, 196, 198,
199, 9999
9999
314 RXA function selection 9999
315 RXB function selection 9999
338 to 340
Parameter for manufacturer setting. Do not set.
342
Communication EEPROM
write selection
0, 1 0
343 Parameter for manufacturer setting. Do not set.
349 Communication reset selection 0, 1 0
450 Second applied motor 0, 1, 9999 9999
495 Remote output selection 0, 1, 10, 11 0
496 Remote output data 1 0 to 4095 0
497 Parameter for manufacturer setting. Do not set.
500
Communication error
execution waiting time
0 to 999.8s 0
501
Communication error
occurrence count display
0 0
502
Stop mode selection at
communication error
0, 1, 2, 3 0
503 Maintenance timer 0 (1 to 9998) 0
504
Maintenance timer alarm
output set time
0 to 9998,
9999
9999
541
Frequency command sign
selection (CC-Link)
0, 1 0
542∗7
Communication station
number (CC-Link)
1 to 64 1
543∗7 Baud rate selection (CC-Link) 0 to 4 0
544∗6 CC-Link extended setting
0, 1, 12, 14, 18
0
547 to 551
Parameter for manufacturer setting. Do not set.
550
NET mode operation
command source selection
0, 2, 9999 9999
551
PU mode operation command
source selection
2 to 4, 9999 9999
555
Current average time 0.1 to 1.0s 1s
556
Data output mask time 0 to 20s 0s
557
Current average value monitor
signal output reference current
0 to 500A
Rated
inverter
current
563
Energization time carrying-
over times
(0 to 65535) 0
564
Operating time carrying-over
times
(0 to 65535) 0
571 Holding time at a start
0 to 10s,
9999
9999
611 Acceleration time at a restart
0 to 3600s,
9999
9999
653 Speed smoothing control 0 to 200% 0
665
Regeneration avoidance
frequency gain
0 to 200% 100
Parameter
Name
Setting
Range
Initial
Value
800 Control method selection 20, 30 20
859 Torque current
0 to 500A (0
to ****) ,
9999
∗5
9999
872 ∗8
Input phase loss protection
selection
0, 1 1
882
Regeneration avoidance
operation selection
0, 1, 2 0
883
Regeneration avoidance
operation level
300 to 800V
400VDC/
780VDC
∗4
885
Regeneration avoidance
compensation frequency limit
value
0 to 10Hz,
9999
6Hz
886
Regeneration avoidance
voltage gain
0 to 200% 100%
888 Free parameter 1 0 to 9999 9999
889 Free parameter 2 0 to 9999 9999
C0 Parameter for manufacturer setting. Do not set.
C2
Frequency setting bias
frequency
0 to 400Hz 0Hz
C3 to C7,
C22 to C25,
990, 991
Parameter for manufacturer setting. Do not set.
Pr.CL Parameter clear 0, 1 0
ALLC All parameter clear 0, 1 0
Er.CL Faults history clear 0, 1 0
Pr.CH Initial value change list
∗1 Differ according to capacities.
6%: 0.75K or lower
4%: 1.5K to 3.7K
3%: 5.5K, 7.5K
2%: 11K, 15K
∗2 Differ according to capacities.
5s: 3.7K or lower
10s: 5.5K, 7.5K
15s: 11K, 15K
∗3 Differ according to capacities.
6%: 0.1K, 0.2K
4%: 0.4K to 7.5K
2%: 11K, 15K
∗4 The initial value differs according to the voltage class. (200V class/400V
class)
∗5 The range differs according to the Pr. 71 setting.
∗6 The setting cannot be changed through the FL remote communication.
∗7 Changing the setting value causes the "L.ERR" LED to flicker. Turn OFF
the power once, then turn ON again (inverter reset) to apply the setting
and to turn OFF the LED.
∗8 Available only for the three-phase power input model.
∗9 Settings cannot be written during CC-Link communication (under
Network operation mode).
Parameter
Name
Setting
Range
Initial
Value