92
Front Panel Power Switch Turned Off while Dishwasher is In-cycle
Rack Control Module Operation
Plate 12:
1. Door closed.
2. POWER Switch OFF.
3. Floats up.
4. Tanks full.
5. Tank heat Disabled.
6. Booster heat disabled.
7. Pumps and drive
disabled.
8. RUN LIGHT OFF.
9. RCM Status light
OFF.
10. All Input and Output
lights OFF.
Rinse Flt L
Wash Flt L
Wash Flt U
Final Rinse
Rack Switch
Jam Switch
Table Limit
Stop
Start
Pause
Power
DR Level
Rinse Flt U
Prewash Flt L
Prewash Flt U
Run
H7
H5 H3
H1
H2
H4
H6
AA
Prewash
DR Tank
Rinse Tank
Digital Display
Rinse
Reset
DR Pump
Pumps
Rinse Aid
Prewash Fill
Wash Fill
Final Rinse
Run Light
DR/Rinse Heat
Wash Heat
Booster Heat
RCM Status/Jumpers
= Indicator ON
= Indicator OFF
NOT USED
NOT USED
NOT USED
NOT USED
This RUN light only shows
power is not supplied to RCM .