Moyer Diebel MD-44 Dishwasher User Manual


 
28
CAUTION:
De-liming agents can cause chemical burns.
Wear rubber gloves, eye protection and any other protective
clothing as instructed by a qualified chemical supplier and follow
the instructions provided by the chemical supplier.
WARNING:
Death or injury can result from toxic fume when de-liming agents
come in contact with Chlorine Bleach, or other chemicals that contain
iodine, bromine, or fluorine.
USE EXTREME CAUTION WHEN HANDLING ANY DE-LIMING AGENT
Cleaning
Cleaning (continued)
At the End of the Day
1. Perform Steps 1-10 on the previous page.
2. Remove the upper and lower rinse and wash spray arms and end plugs and ush with fresh water.
3. Clean the nal rinse arm nozzles using a small paper clip.
4. Remove the curtains and clean with fresh water.
DO NOT USE STEEL WOOL TO CLEAN THE INTERIOR OF THE MACHINE.
Wipe the interior and exterior of the machine with a soft cloth and a mild detergent.
DO NOT HOSE THE EXTERIOR OF THE MACHINE WITH WATER.
5. Reassemble the dishwasher and leave the door open to allow overnight drying
6. Contact the chemical supplier for de-liming if required.
De-liming
Lime (scale) deposits are the result of minerals contained in the water feeding the dishwasher and appear
as a white haze on the surface of the dishwasher. Severe scaling can appear as a granular deposit.
These deposits are a result of the mineral content in the geographic area of the machine's location.