Chapter 2 Measurement & Automation Explorer (Windows)
© National Instruments Corporation 2-5 NI-488.2 User Manual
Scan for GPIB Instruments
To scan for instruments connected to your GPIB interface or to add a new
instrument to your system, complete the following steps:
1. Make sure that your instrument is powered on and connected to your
GPIB interface.
2. Start Measurement & Automation Explorer as described in the
Starting Measurement & Automation Explorer section.
3. Expand the Devices and Interfaces directory by clicking the + next
to the folder.
4. Right-click on your GPIB interface and select Scan for Instruments
from the drop-down menu that appears.
Measurement & Automation Explorer displays the connected
instruments in the right window pane.
Instruments Not Found
If Measurement & Automation Explorer reports that it did not find any
instruments, make sure that your GPIB instruments are powered on and
properly connected to the GPIB interface with a GPIB cable. Then, scan for
instruments again, as described in the Scan for GPIB Instruments section.
Too Many Listeners on the GPIB
If Measurement & Automation Explorer reports that it found too many
Listeners on the GPIB, refer to the following possible solutions:
If you have a running GPIB Analyzer with the GPIB handshake option
enabled, disable the GPIB handshake option in the GPIB Analyzer.
If you have a GPIB extender in your system, Measurement &
Automation Explorer cannot detect any instruments connected to
your GPIB interface. Instead, you can verify communication with
your instruments using the Interactive Control utility. To do so,
select Tools»NI-488.2»Interactive Control. For more
information about verifying instrument communication, type
help
at the Interactive Control command prompt.