Pitco Frialator L20-378 Fryer User Manual


 
INSTALLATION
L20-378 rev. 0 (9/12) 15
If your appliance is equipped with SPINFRESH
TM
, the tank enclosure can interfere with the
performance of pre-existing fire safety systems. Modifications to the fire safety system should be
performed by a professional who is qualified in installing, designing and maintaining your fire safety
system prior to operating any SPINFRESH
TM
appliance.
1.7. INSPECTION
Before you begin filling and adjusting the appliance, perform the following visual checks:
After the appliance is in its permanent location, check the levelness. Any additional leveling that
is necessary can be performed as previously described.
Ensure that the probe and high temperature limit is in place and secure. Check the high limit
bulb mounting screws to ensure that they are tight.
Review the installation portion of this manual and ensure that all steps have been followed and
executed properly.
1.8. INITIAL ADJUSTMENTS
After your appliance has been properly installed as described in the installation section of this
manual, it will need to be adjusted to ensure that it will perform as designed. A qualified person must
perform these adjustments.
1) Probe
2) High Temperature Limit
WARNING
Ensure that your ventilation system does not cause a down draft at the appliance’s flue
opening. A down draft will not allow the appliance to exhaust properly and will cause
overheating, which may cause permanent damage. Damage caused by down drafts will not
be covered by the warranty. NEVER allow anything to obstruct the flow of combustibles or
ventilation exiting the appliance. NEVER place anything on top of the flue area, or block the
flue in any way. Never place a grease condensing drip pan over the flue opening.
WARNING
NEVER connect the ventilation blower or hood directly to the flue of this appliance. The
resulting increased flow of air through the combustion system will cause improper
operation, poor temperature recovery, poor ignition and could extinguish the pilot.
WARNING
Replacing or adding appliances under a pre-existing fire safety system may require
modifications to the system. ALWAYS contact a professional who is qualified in installing,
designing and maintaining your fire safety system to assure that any appliances located
under the fire safet
y
s
y
stem are adequatel
y
protected.