4 To Enter Programming Level 3 (for the Technician)
With no cook timers running, displays will show one of the following displays:
; , or .
Press the key. The left display will show . The right display
will be blank.
Enter password
686
5
Level 3 Password
using the product keys as a numeric keypad for
entry.
Display will show . Product key indicators will
illuminate to prompt operator to select a key. This section details
parameters that may be changed in Level 3 programming.
4.1 Offset the Temperature Display:
This adjustment allows the displayed temperature value to be offset to reflect the true
center vat temperature while reading the probe tip temperature. Default value is +2.
With zero value set, displayed values are the probe temperature.
With display showing
press product key 1.
Display shows [OFF nn F] [DEGREES], where “nn” is the value of the adjustment.
Negative values are preceded with a minus sign. To change this value, use the product keys
for numeric entry of a new value.
Press the key. Display will show [POSITIVE] [DEGREES]. Use the product key to scroll
choices (Positive or Negative value).
After selection, press the key. Display shows .
Note: Computer Display Temp Center Vat Temp = Offset (+/-). Example: Computer Display shows
350F while Center Vat Temp measures 352F. 350F – 352F = - 2 °F. A negative offset value. Proper
equipment and expertise is required to correctly adjust this value. Even small changes may negatively
affect cooking performance.
4.2 Melt Cycle ON Time
With display showing press product key 2.
Display shows [MLTON :nn] [MELT ON], where “nn” is the value, in seconds, of time
for a melt cycle heat pulse.
To change this value, use the product keys for numeric entry of a new value.
Press the key. Display returns to .