Technical Data
This cooker is designed for use on either :-
NATURAL GAS
ES Cat I2H G20mbar at 20mbar
ES Cat 12E+, G20 at 20mbar/G25 at 25mbar
FR/ES Cat I3+ G30 at 28mbar, G31 at 37mbar
NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT MODELS AND
CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : LOWER RIGHT HAND COOKER UPRIGHT (Remove storage drawer)
Country of Destination: GB/IE
Gas Electric
Natural Gas 20/25mbar 220 - 240V 50Hz
Butane 28/30mbar
Propane 37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height including optional
splashback
minimum 1060mm maximum 1090mm
Overall height
minimum 893mm maximum 920mm
Overall width
1100mm See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas: Electric
Rp
1
/
2
at rear right-hand side 220 - 240V 50Hz
Ratings
Natural Gas L.P. Gas
Hotplate
Injector Injector
Wok burner
3.5kW
internal 80
3.5kW (246g/h)
internal 54
external 129 external 77
Large Burner
3.0kW 134 3.0kW (210g/h) 87
Medium Burners
1.7kW 109 1.7kW (119g/h) 68
Small Burner
1.0kW 75 1.0kW (70g/h) 51
Ovens
3.2kW 237 2.9kW (224g/h) 85
Grill
2.73kW 190 2.73kW (192g/h) 85
Gas burner inputs based on Gross Calorific Value
Warmer
160W