Roper D975 Oven User Manual


 
INSTALL RANGE
BE SURE RANGE BRANCH CIRCUIT IS DE-
ENERGIZED.
I
IMPORTANT SAFETY WARNING
1. Remove Oven Door
n
Open the door to the stop
position (see illustration).
l
Grasp the door at each side and
lift
up and off the
hinges.
NOTE: When the door is removed and hinge arms are at
stop position, do not bumportry to move the hinge arms. The
hinges could snap back causing injury to the hands Or
damage to the porcelain on the front of the range. Cover the
hinges with toweling or empty towel rolls while working in the
oven area.
Be sure to attach range to counter and
be sure counter top is securely attached
to the cabinets or wall.
A
Failure to do so could permit the range
to tip, causing injury.
STOP POSITION
To replace:
VENT TRIM
l
Hold the door over the hinges with the slots at the bottom
edge of the door lined up with the hinges. The hinge arms
must still be in the stop position.
l
Slide the door down onto the hinges as far as it will go and
close the door.
2. Position range in opening.
l
Raise lift-up cooktop and support it with cooktop
support rod.
l
Drill 118” diameter pilot holes into countertop using
holes in upper side panels. Attach range to countertop
(Fig.
4)
with screws provided in literature package.
EINS30-2