Southbend EZ-3/EZ-5 Electric Steamer User Manual


 
TROUBLESHOOTING MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS
Figure 17
Door Switch Continuity Check (for units built after January 15, 2001)
Terminal Block
Door Switch
1. Disconnect power at circuit breaker.
2. Remove control panel.
3. Depress and release door switch actuator rod to make sure door switch is properly actuated.
4. Remove door switch lead wires from terminal block position 1 and terminal 8 of the controller.
5. Place test lead as shown inside the terminal connectors of the lead wires.
6. Check for continuity - (there should be NO continuity).
7. Depress door switch actuator rod and check for continuity - (there should be continuity).
TROUBLESHOOTING
PAGE 28 OPERATORS MANUAL 1178387 REV 5