TROUBLESHOOTING MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS
Figure 19
High Limit Continuity Check (for units built before January 15, 2001)
C16 C19
C58 C59
Terminal Bloc
k
Model EZ-3
Model EZ-5
1. Turn unit off.
2. Wait for cavity bottom to cool to touch.
3. Disconnect power at circuit breaker.
4. Remove control panel without disconnecting plug.
5. EZ-3: Remove wires C16 and C19 from terminal block positions 1and 2, as shown; or
EZ-5: Remove wires C58 and C59 from terminal block positions 5 and 6, as shown.
6. EZ-3: Place test leads as shown inside the terminal connectors of wires C16 and C19, or
EZ-5: Place test leads as shown inside the terminal connectors of wires C58 and C59.
7. Check for continuity.
8. If no continuity, disconnect each high limit switch individually and check for continuity. Replace
switches that do not have continuity. (See Figure 14 on page 25 for typical high limit switch
location.)
9. EZ-3: Reconnect wires C16 and C19; or
EZ-5: Reconnect wires C58 and C59.
10. Reconnect power at circuit breaker.