Southbend SEZ/3 Electric Steamer User Manual


 
TROUBLESHOOTING SEZ SERIES COUNTERTOP STEAMERS
PAGE 20 OPERATORS MANUAL 1183437
TROUBLESHOOTING
Unit Not Heating Up Properly or Not Cooking Properly, “ON” Light Lit
Unit not heating up properly or not cooking properly, “ON” light lit.
Reconnect power to unit.
Turn unit on. WAIT 5 MINUTES.
Does contactor
“click” on and stay on
for at least 2
minutes?
No
Yes
DISCONNECT POWER AT CIRCUIT BREAKER. DISCONNECT POWER AT CIRCUIT BREAKER.
Remove control panel.
Remove control panel.
Check resistance between contactor terminals and
replace elements as necessary (see Figure 8 on
page 25).
Continuity?
Replace door switch.
No Yes
Check door switch for continuity (see Figure 13 on
page 30).
Reconnect door switch
lead wires.
Remove rear cover.
Check pressure switch for
proper operation (see
Figure 17 on page 34).
Pressure switch OK?
Check and replace
contactor (see Figure 11
on page 28) and/or
controller (see Figure 15
on page 32),
as necessary.
Replace pressure switch.
No Yes
DISCONNECT POWER AT THE CIRCUIT BREAKER.
Check all three main fuses; replace as necessary (see Figure 9 on page 26).
Open door; depress and hold door switch.
Check high-limit
thermostats (see
Figure 18 on page 35).
High-limit
thermostats
OK?
Replace high-limit
thermostats
as necessary.
No Yes